Ins-30062 Energy saving reader - EM4100
09/11/2011
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
01273 811011 [email protected]
Fitting
When a valid user card is introduced to the reader, its card number is sent to the controller. The reader
constantly monitors for the presence of that card and once it is no longer in range of the reader (removed from
the holder) the card number is sent a second time. Paxton control units have a toggle function that will change
the state of the relay each time it receives a card number.
The system only monitors one card at a time and so a short 'off' period will occur if the user card in the holder is
exchanged for another.
Switch2 must be congured by means of a Toggle function card - This will need to be purchased if no function
pack already exists for this site.
Net2 software has a toggle function so either Reader port 1 or 2 can be used for this function. You will need to
select the Relay 2 toggle mode on the relevant reader screen.
Operation
Paxton controller relays must NOT be connected directly to the mains supply.
See: AN1088 - Using the energy saving reader. < http://paxton.info/787 >
This proximity reader has a special cover that is designed to retain a user card. The presence of a card in the
reader can then be used to turn on/off other equipment when a user is present.
A reader and controller can be used to provide a voltage free relay toggled output that can either directly switch low
voltage (less than 24V DC) or, in conjunction with a mains contact relay, switch power to equipment or lighting.
How is it used?
If the Access level of a card becomes invalid (e.g. the time period or date expires) while it is in the reader,
removing the card will NOT turn off the equipment. You will need to introduce and remove a valid card to correct
this condition.
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Paxton
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - How is it used?

Ins-30062 Energy saving reader - EM410009/11/2011Technical SupportTechnical help is available: Monday - Friday from 07:00 - 19:00 (GMT)

Page 2 - Connection modules

WHITE labelled control units provide 5V at the Red terminal. The Red power wire for the reader should therefore be directly connected to the 12V supp

Page 3 - Specications

The declaration of conformity is available on request. Contact details are provided at: http://paxton.info/596Voltage Clock and data bit period Carr